- New
- Sale
- Temperature
- Humidity
- Pressure
- Light Intensity & Motion
- Air Quality
- Flow
- Modbus | Wireless Modbus
- Room controller
- EtherCAT P
- Accessory
Description
Room humidity, temperature and CO2 sensor or measuring transducer
AERASGARD®
TheAERASGARD® FSFTM - CO2 - Modbus room sensor and measuring transducer with in-wall enclosure and optional potentiometer is used to measure The CO2 content, relative humidity and temperature of the air, and for setpoint adjustment. The measured values are queried via the Modbus interface.
The CO2 content of the air is measured using an optical NDIR sensor (non-dispersive infra- red technology). A digital, long-term stable sensor is used for humidity and temperature measurement. Relative humidity [% r.H.] is the quotient of water vapour partial pressure divided by the saturation vapour pressure at the respective gas temperature.
The in-wall transmitter is mounted either individually or in combination with light switches, socket outlets, etc. in high-quality panel switch brand programmes, such as preferably from Gira, Berker, Merten, Jung, Siemens or Busch-Jaeger (with in-wall adapters, no setpoint adjustment possible).
The CO2 content of the air is measured using an optical NDIR sensor (non-dispersive infra- red technology). A digital, long-term stable sensor is used for humidity and temperature measurement. Relative humidity [% r.H.] is the quotient of water vapour partial pressure divided by the saturation vapour pressure at the respective gas temperature.
The in-wall transmitter is mounted either individually or in combination with light switches, socket outlets, etc. in high-quality panel switch brand programmes, such as preferably from Gira, Berker, Merten, Jung, Siemens or Busch-Jaeger (with in-wall adapters, no setpoint adjustment possible).
It is used in non-aggressive, dust-free environments, in refrigeration, air conditioning and cleanroom engineering, and in interior spaces, such as living rooms, offices, hotels, etc.
Technical details
Data points
temperature, relative humidity, carbon dioxide (CO2)
Warm up time
approx. 1 hour
Response time
< 2 minutes
Long-term stability
< 2 % in 15 years
± 1 % per year
± 1 % per year
Protection class
III (according to EN 60 730)
Protection type
IP 20 (according to EN 60 529)
Protection type housing
IP 20
Standards
CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU
electromagnetic compatibility according to EN 61326,