New
°C + % RH + VOC
Si Imp Modbus

Room controller (controller) RYMASKON® RYM 1462C-RH-VOC-MOD-BB

SKU RYM1-4621-M710-002 EAN 4 251325 639550 Product group: WG02
In stock , available in 1-3 working days
plus 19% VAT., plus. shipping
incl. VAT 518,84 €
Shipping calculated at checkout.
Regular price 436,00 €
Regular price Sale price 436,00 €

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

Rymaskon® 1000 C Controller - 24V
  • Temperature [°C] [°F],
    relative humidity [% RH],
    air quality (VOC) [%] [ppb]
  • Control: temperature, fans, solar shading
  • Output: Modbus RTU, 0-10V, switched outputs
  • Input: 1x NTC10K, 1x digital
  • Power supply: 24 V AC / DC
  • Flush-mount installation
  • IP30
The room operating units of the series Rymaskon® 1000 are designed for controlling (up to 2 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan stages of the interior. The controller variants can be operated as stand-alone devices using the integrated control functions PI, PWM or 2-/3-point control. The product family is characterized by an elegant design, intuitive operation and a wide range of possible combinations of the individual components.
The room operating units Rymaskon® 1000 C (controller) are used to control and regulate heating fan convectors and fan coil units (Fancoil). Depending on the type variant, the units are available with analog outputs (0 -10 V) and with digital / relay outputs for controlling heating valves, cooling valves, 6-way valves, step-controlled fans or EC fans. The control is carried out via PI, PWM or 2-/3-point control. With the changeover function, 2- and 4-pipe systems can be operated.
The Modbus communication interface or W-Modbus enables the configuration and monitoring of the climate parameters on the controller at any time via the BMS (building management system). In addition, functions such as solar shading (roller shutters, venetian blinds) or lighting (with dimming function) can be controlled over the bus. The optical display is provided by a 2" TFT display; operation is via capacitive keys (Touchkeys).

In addition to the integrated temperature and humidity sensor, CO2 and VOC sensors are available optionally. Furthermore, an input is available for a passive temperature sensor (NTC10K) and an input for a potential-free contact. This enables, for example, a window contact or a condensation monitor to be connected. This means that all options are available to climate-control rooms flexibly and individually.
All device types are available in the timeless housing Iduna 3 (112 x 89.5 x 24 mm) in the colors white or black. Wall mounting is carried out on standard flush-mounting boxes.

Technical data

Type of function Controller
Measured variables Temperature, relative humidity, air quality (VOC)
Communication Modbus RTU
Power supply 24 V AC/DC (± 10 %)
Output 0-10V + switching output
Color Black
Display Yes
Measured variable in addition to °C + %RH + VOC

Blog posts

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, it's not just precision that...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, i...

Der neue LS-Flex: Leckagen an Rohren schneller entdecken

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With...

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With the LS-Flex we of...

Hochfeuchte im Griff – mit diesen Spezialisten

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors have long...

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors hav...

Kanalfeuchtefühler im Blick: Präzise, zuverlässig, preiswert – bei jeder Messung

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it comes...

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it...

Kanalfühler im Fokus – So steigern Sie Energieeffizienz und Betriebssicherheit

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Druck im System? So behalten Sie Temperatur & Feuchte im Griff!

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed for use...

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed ...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST