New
°C + % RH + VOC
W Modbus IMP

WIRELESS room controller (controller) RYMASKON® RYM 1431C-RH-VOC-WMOD

SKU RYM1-4311-W710-000 EAN 4 251325 626956 Product group: WG02
In stock , available in 1-3 working days
plus 19% VAT., plus. shipping
incl. VAT 544,25 €
Shipping calculated at checkout.
Regular price 457,42 €
Regular price Sale price 457,42 €

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

Rymaskon® 1000 C Controller - 24V
  • Temperature [°C] [°F],
    relative humidity [% RH],
    air quality (VOC) [%] [pbb]
  • Control: Temperature, fan
  • Output: W-Modbus, 0-10V
  • Input: 1x NTC10K, 1x digital
  • Power supply: 24 V AC / DC
  • Flush-mount installation
  • IP30
The room controllers of the Rymaskon® 1000 series are designed to control (up to 2 HVAC zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan stages of the interior. The controller variants can be operated as stand-alone devices using the integrated control functions PI, PWM or 2-/3-point control. The product family is distinguished by its elegant design, intuitive operation and the diverse combination options of the individual components.
The room controllers Rymaskon® 1000 C (controller) are used to actuate and control heating fan coil units and blower fan coil units (fan coils). Depending on the type variant, the units are available with analog outputs (0 -10 V) as well as with digital/relay outputs for controlling heating valves, cooling valves, 6-way valves, stepped fan stages or EC fan stages. Actuation is carried out via PI, PWM or 2-/3-point control. With the changeover function, 2- and 4-pipe systems can be operated.
The Modbus communication interface or W-Modbus enables the controller to change and monitor climate parameters at any time via the BMS. In addition, functions such as solar shading (roller shutters, blinds) or lighting (with dimming function) can be controlled over the bus. Visual indication is provided via a 2" TFT display, and operation is via capacitive keys (touchkeys).

In addition to the integrated temperature and humidity sensor, sensors for CO2 and VOC are available as options. Furthermore, an input is available for a passive temperature sensor (NTC10K) and an input for a potential-free contact. This means, for example, that a window contact or a condensate sensor can be connected. This provides all the options needed to flexibly and individually condition rooms.
All device types are available in the timeless Iduna 3 enclosure (112 x 89.5 x 24 mm) in white or black. Wall mounting is carried out on standard flush-mounting boxes.

Technical data

Function type Controller
Measured values Temperature, relative humidity, air quality (VOC)
Communication W-Modbus
Power supply 24 V AC/DC (± 10 %)
Output 0-10V
Color White
Display Yes
Protection class IP30
Measured variable in addition to °C + %RH + VOC

Blog posts

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, it's not just precision that...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, i...

Der neue LS-Flex: Leckagen an Rohren schneller entdecken

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With...

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With the LS-Flex we of...

Hochfeuchte im Griff – mit diesen Spezialisten

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors have long...

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors hav...

Kanalfeuchtefühler im Blick: Präzise, zuverlässig, preiswert – bei jeder Messung

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it comes...

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it...

Kanalfühler im Fokus – So steigern Sie Energieeffizienz und Betriebssicherheit

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Druck im System? So behalten Sie Temperatur & Feuchte im Griff!

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed for use...

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed ...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST