New
°C + % RH + VOC
W Modbus IMP

WIRELESS room controller (controller) RYMASKON® RYM 1362C-RH-VOC-WMOD

SKU RYM1-3621-W710-000 EAN 4 251325 627595 Product group: WG02
In stock , available in 1-3 working days
plus 19% VAT., plus. shipping
incl. VAT 544,25 €
Shipping calculated at checkout.
Regular price 457,42 €
Regular price Sale price 457,42 €

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

Rymaskon® 1000 C Controller - 24V
  • Temperature [°C] [°F],
    relative humidity [% RH],
    air quality (VOC) [%] [pbb]
  • Control: Temperature
  • Output: W-Modbus, 0-10V, switching
  • Input: 1x NTC10K, 1x digital
  • Power supply: 24 V AC / DC
  • Flush-mounted installation
  • IP30
The room control units of the series Rymaskon® 1000 are designed for controlling (up to 2 climate zones) in residential, hotel, and office rooms and individually regulate the heating, cooling and fan stages of the interior space. The controller variants can be operated as stand-alone devices using the integrated control functions PI, PWM or 2-/3-point control. The product family stands out for its elegant design, intuitive operation and the versatile combination options of the individual components.
The room control units Rymaskon® 1000 C (controller) are used to control and regulate heating fan convectors and cooling fan convectors (fan coil). Depending on the type variant, the units are available with analog outputs (0 -10 V) as well as with digital-/relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is performed via PI, PWM or 2-/3-point control. With the changeover function, 2- and 4-pipe systems can be operated.
The Modbus communication interface or W-Modbus enables the continuous changing and monitoring of climate parameters on the controller via the BMS (building management system). In addition, functions such as solar shading (roller shutters, blinds) or lighting (with dimming function) can be controlled via the bus. The optical indication is provided by a 2" TFT display; operation is via capacitive buttons (touchkeys).

In addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. Furthermore, an input is provided for a passive temperature sensor (NTC10K) and an input for a potential-free contact. This allows, for example, a window contact or a condensation monitor to be connected. This ensures that all options are available to flexibly and individually climate-control the rooms.
All device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in the colors white or black. Wall mounting is done on standard flush-mounting back boxes.

Technical data

Type of function Controller
Measured variables Temperature, relative humidity, air quality (VOC)
Communication W-Modbus
Power supply 24 V AC/DC (± 10%)
Output 0-10V + switched output
Color Black
Display Yes
Ingress protection IP30
Measured variable in addition to °C + %RH + VOC

Blog posts

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, it's not just precision that...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, i...

Der neue LS-Flex: Leckagen an Rohren schneller entdecken

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With...

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With the LS-Flex we of...

Hochfeuchte im Griff – mit diesen Spezialisten

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors have long...

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors hav...

Kanalfeuchtefühler im Blick: Präzise, zuverlässig, preiswert – bei jeder Messung

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it comes...

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it...

Kanalfühler im Fokus – So steigern Sie Energieeffizienz und Betriebssicherheit

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Druck im System? So behalten Sie Temperatur & Feuchte im Griff!

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed for use...

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed ...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST