New
°C + % RH + CO2
W Modbus IMP

WIRELESS room controller (controller) RYMASKON® RYM 1312C-RH-CO2-WMOD-LL

SKU RYM1-3121-W620-004 EAN 4 251325 635484 Product group: WG02
In stock , available in 1-3 working days
plus 19% VAT., plus. shipping
incl. VAT 624,75 €
Shipping calculated at checkout.
Regular price 525,00 €
Regular price Sale price 525,00 €

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

Rymaskon® 1000 C Controller - 230V
  • Temperature [°C] [°F],
    relative humidity [% RH],
    carbon dioxide (CO2) [ppm]
  • Control: temperature, light
  • Output: W-Modbus, 0-10V, switching contact
  • Input: 1x NTC10K, 1x digital
  • Power supply: 230 V AC
  • Flush-mounted installation
  • IP30
The room controllers of the Rymaskon® 1000 series are designed to control (up to 2 HVAC zones) in residential, hotel and office rooms, and individually regulate the heating, cooling and fan stages of the interior space. The controller variants can be operated as stand-alone devices using the integrated control functions PI, PWM or 2-/3-point control. The product family is characterized by its refined design, intuitive operation and the many combination options of the individual components.
The room controllers Rymaskon® 1000 C (controllers) are used for the actuation and control of heating fan convectors and blower fan convectors (fan coils). Depending on the type variant, the devices are available with analog outputs (0 - 10 V) as well as with digital / relay outputs, for controlling heating valves, cooling valves, 6-way valves, stepped fans or EC fans. The actuation is carried out via PI, PWM or 2-/3-point control. With the changeover function, 2- and 4-pipe systems can be operated.
The Modbus communication interface or W-Modbus enables the controller to change and monitor HVAC parameters at any time via the BMS. In addition, the functions solar shading (roller shutters, blinds) or lighting (with dimming function) can be controlled over the bus. The optical display is provided via a 2" TFT display; operation is via capacitive buttons (touchkeys).

In addition to the integrated temperature and humidity sensor, sensors for CO2 and VOC are available optionally. Furthermore, an input is available for a passive temperature sensor (NTC10K) and an input for a potential-free contact. This makes it possible, for example, to connect a window contact or a condensation monitor. This ensures that all options are available to flexibly and individually condition the rooms.
All device types are available in the timeless housing Iduna 3 (112 x 89.5 x 24 mm) in the colors white or black. Wall mounting is performed on standard flush-mounted junction boxes.

Technical data

Type of function Controller
Measured variables Temperature, relative humidity, CO2
Communication W-Modbus-W-BACnet
Power supply 230 V AC (100-240 V AC)
Output 0-10V + switching output
Color Black
Display Yes
Protection class IP30
Measured quantity in addition to °C + %RH + CO2
Communication/Interface W-Modbus (Wireless Modbus, AES-128 encrypted),
Frequency 2.4 GHz ISM, transmit power 100 mW,
Range max. 500 m (open field) / approx. 50 - 70 m (building),
Slave, address range 1–247, max. 100 devices per gateway,
Building management system (BMS) connection is made wirelessly via W-Modbus-gateway

Blog posts

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous...

High-humidity sensors in the food industry and ...

High humidity places special demands on the sensors used in many applications. In our previous ar...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, it's not just precision that...

CuRA - Customized Register Assignment

Define Modbus registers flexibly, individually and project-specifically In building automation, i...

Der neue LS-Flex: Leckagen an Rohren schneller entdecken

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With...

The new LS-Flex: Detect leaks in pipes more qui...

Early detection of water leaks is now not just an option, but a necessity. With the LS-Flex we of...

Hochfeuchte im Griff – mit diesen Spezialisten

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors have long...

High humidity under control – with these specia...

Perfect performance – our special solutions for extreme humidity Where other humidity sensors hav...

Kanalfeuchtefühler im Blick: Präzise, zuverlässig, preiswert – bei jeder Messung

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it comes...

Duct humidity sensors in focus: Precise, reliab...

in measurement and control technology, precision and reliability are crucial - especially when it...

Kanalfühler im Fokus – So steigern Sie Energieeffizienz und Betriebssicherheit

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Focus on duct sensors - how to increase energy ...

In modern HVAC systems, the precise detection of humidity and temperature in the ventilation duct...

Druck im System? So behalten Sie Temperatur & Feuchte im Griff!

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed for use...

Pressure in the system? How to keep temperature...

Made for extreme conditions - HYGRASGARD® humidity and temperature sensors - specially developed ...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST