°C
%RH

Product description
- 0...100 % RH
0...+50 / −20...+80 / −30...+70 / 0...+100 °C - Temperature [°C], relative humidity [% RH],
dew point [°C], absolute humidity [g / m3],
mixing ratio [g / kg] - 4...20 mA
- Nominal pressure: 10 bar
- IP 65
Calibratable HYGRASGARD® ESFTF screw-in sensor in a housing made of impact-resistant plastic with quick-locking screws, with cable gland (optional M12 plug connector to DIN EN 61076-2-101), threaded duct pipe (G1/2") and metal sintered filter (replaceable).
The sensor is used to measure relative humidity (0...100 % RH) and temperature (4 switchable measuring ranges) in compressed air lines up to max. 10 bar. The transducer converts the measured variables into a standard signal of 4...20 mA or 0 - 10 V. Further parameters are calculated internally from the measured variables and can be called up via the humidity output: absolute humidity, mixing ratio and dew point temperature (switchable via DIP switch).
The device also has a sensor protection function for high humidity (95...99 % RH). The measuring element is automatically heated in the critical range and thus protected against condensation. The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment. It must be installed vertically with the humidity sensor facing downwards.
The sensor is used to measure relative humidity (0...100 % RH) and temperature (4 switchable measuring ranges) in compressed air lines up to max. 10 bar. The transducer converts the measured variables into a standard signal of 4...20 mA or 0 - 10 V. Further parameters are calculated internally from the measured variables and can be called up via the humidity output: absolute humidity, mixing ratio and dew point temperature (switchable via DIP switch).
The device also has a sensor protection function for high humidity (95...99 % RH). The measuring element is automatically heated in the critical range and thus protected against condensation. The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment. It must be installed vertically with the humidity sensor facing downwards.
Technical data
| Measurement | temperature, relative humidity, dew point, absolute humidity, mixing ratio |
| Power supply | 24 V AC/DC (± 10 %) for the U variant; 15...36 V DC for the I variant, depending on |
| Display | No |
| Cable connection | plastic cable gland (M 16 x 1.5; with strain relief, replaceable, inner diameter 10.4 mm) or M12 plug connector (in-line plug, 5-pin, A-coded) according to DIN EN 61076-2-101 (optional on request) |
| Output | 4...20 mA |
| Output | 4...20 mA |
| Humidity sensor tolerance | 2 % |
We also manufacture individually
Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.
Contact us
Secure payment methods
Do you have a question? We are at your disposal:
+49 911 519 470
Mo. - Fr. 7.00am - 5.00pm CEST