Room CO2 sensor and measuring transducer RCO2-W LCD
temperature CO2

Room CO2 sensor and measuring transducer AERASGARD® RCO2-W LCD

Item no. 1501-61B0-7321-200
EAN 4251325613130
Product group: WG02

In Stock

Usually ships in 1 to 3 days
307,21 €
365,58 € incl. VAT + shipping
+

Description

Room CO2 sensor and measuring transducer AERASGARD® RCO2-W
Maintenance-free AERASGARD® RCO2 - SD room air quality measuring transducer with active output, automatic calibration (fixed), in an elegant plastic housing with snap-on cover, for determining the CO2 content of the air (0...2000 ppm). The transmitter converts the measured values into a standard signal of 0-10 V.

Maintenance-free AERASGARD® RCO2 - W room air quality measuring transducer with active/switching output, automatic calibration (can be deactivated), in an elegant plastic housing with snap-on cover, optional with traffic light indicator (five coloured LEDs), for determining the CO2 content of the air (0...2000 ppm/0...5000 ppm). The transmitter converts the measured values into a standard signal of 0-10 V or 4...20 mA (switchable).

The sensor device is used in offices, hotels, convention centres, apartments, shops, etc. for the purpose of evaluating the indoor climate. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being.
The CO2 content is measured using an optical NDIR sensor (non-dispersive infra-red technology). The detection range is calibrated for standard applications such as the monitoring of residential and conference rooms.

Technical details

Voltage supply
24 V AC/ DC (± 10 %)
Power consumption
< 1.5 W/ 24 V DC typical;
< 2.9 VA/ 24 V AC typical;
peak current 200 mA
Measuring accuracy
typically ± 30 ppm ± 3 % of measured value
Temperature dependence, CO2
± 5 ppm/ °C or ± 0.5 % of measured value/ °C
(whichever is higher)
Pressure dependence
± 0,13 %/ mm Hg
Gas exchange
by diffusion
Warm up time
approx. 1 hour
Response time
< 2 minutes
Ambient temperature
0...+50 °C
Electrical connection
0.14 - 1.5 mm² via terminal screws
Service life
> 60 months (under normal load conditions)
depending on the type of loading and gas concentration
Measuring range, CO2
0...2000 ppm / 0...5000 ppm
Long-term stability
< 2 % in 15 years
Output, CO2
0 -10 V or 4...20 mA (selectable via DIP switches)
Protection class
III (according to EN 60 730)
Protection type
IP 30 (according to EN 60 529)
Protection type housing
IP 30
Relay output
with potential-free changeover contact 24 V (assignment selectable via DIP switches)
Output
0 -10 V or 4...20 mA, working resistance < 800 Ω
(selectable via DIP switches)
with offset potentiometer (± 10 % of the measuring range
Sensor
Optical NDIR sensor (non-dispersive infra-red technology),

with manual calibration (via zero button),
with automatic calibration (can be deactivated via DIP switches)
Measuring range
0...2000 ppm or 0...5000 ppm (selectable via DIP switches)
Housing
plastic, material ABS,
colour pure white (similar to RAL 9010)
Dimensions
98 x 98 x 33 mm (Baldur 2)
Installation
wall mounting or on in-wall flush box, Ø 55 mm,
base with 4 holes, for attachment to vertically or
horizontally installed in-wall flush boxes for rear cable entry,
with predetermined breaking point for cable entry
from top/ bottom in case of plain on-wall installation
Standards
CE conformity, electromagnetic compatibility
according to EN 61 326, EMC Directive 2014/ 30/ EU,
Low Voltage Directive 2014/ 35/ EU
Display
with display for displaying the actual CO2 content in ppm