Duct humidity sensor/ Duct humidity and temperature sensor KFF-SD-U

Duct humidity sensor HYGRASGARD® KFF-SD-U

Item no. 1201-3181-0000-029
EAN 4251325610481
Product group: WG01B

In Stock

Usually ships in 1 to 3 days
167,18 €
198,94 € incl. VAT + shipping
+

Description

Duct humidity and temperature sensor HYGRASGARD® KFF-SD
Calibratable HYGRASGARD® KFF - SD / KFTF - SD duct humidity/temperature sensor (±2.0%), with plastic sinter filter (metal sinter filter optional), housing made of impact resistant plastic with snap-on cover.
The transmitter measures relative humidity and/or air temperature and converts the measurands into a standard signal of 0-10 V or 4...20 mA. It supports four switchable temperature ranges and is applied in non-aggressive dust-free atmospheres in refrigeration, air conditioning, ventilation and cleanroom engineering. The measuring transducer provides precise detection of humidity. A digital long-term stable sensor is used as measuring element for humidity. The sensor is factory-calibrated and can be fine-tuned to ambient conditions by an expert.

Technical details

Voltage supply
24 V AC (± 20 %) and
15…36 V DC
Power consumption
< 1.1 VA/ 24 V DC ; < 2.2 VA/ 24 V AC
Data points
Relative humidity [% RH]
Load resistance
RL > 5 kOhm
Measuring range, humidity
0...100 % RH
Deviation of humidity
typical ± 2 % RH (20…80 % RH ); at + 25 °C, otherwise ± 3 %
Output, humidity
0 - 10 V
Measuring range, temperature
multi-range switching
with 4 switchable measuring ranges
–35...+35 °C; –35...+75 °C; 0...+50 °C; 0...+80 °C
(output corresponding to 0 -10 V or 4...20 mA)
Sensor protection
plastic sinter filter, Ø 16 mm, L = 35 mm, exchangeable
(optional metal sinter filter, Ø 16 mm, L = 32 mm)
Measuring range
0...100 % RH
Process connection
by mounting flange, plastic
(included in the scope of delivery)
Protective tube
PLEUROFORM, material polyamide (PA6), with torsion protection,
Ø 20 mm, NL = 235 mm (optionally 100 mm), vmax = 30 m/s (air)
(option on request in stainless steel V2A (1.4301), Ø 16mm)
Electrical connection
2-, 3- or 4-wire connection
0.14 -1.5 mm ² via terminal screws on circuit board
Cable connection
cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or
M12 connector according to DIN EN 61076-2-101 (optional on request)
Housing
plastic, UV-stabilised,
material polyamide, 30 % glass-globe-reinforced
colour traffic white (similar to RAL 9016)
ALTF 02 with snap-on lid,
Housing dimensions
72 x 64 x 37.8 mm (Tyr 01)
Cable gland
M 16 x 1.5, including strain relief, exchangeable,
max. inner diameter 10.4 mm
Long-term stability
± 1 % per year
Permissible air humidity
< 95 % RH, non-precipitating air
Protection class
III (according to EN 60 730)
Protection type
IP 54 (according to EN 60 529) Housing tested,
TÜV SÜD, Report No. 713160960A (Tyr 01)*
Protection type housing
IP 54
Standards
CE conformity,
according to EMC directive 2014/ 30/ EU,
according to EN 61326-1, according to EN 61326-2-3