Menu
Pressure
Luftfeuchtigkeit
Temperature
PREMASGARD® 814x - Modbus

Duct humidity and temperature sensors with integrated pressure and differential pressure measuring transducer PREMASGARD® 814x - Modbus

In Stock.

Usually ships in 1 to 3 days
491,72 €
Price plus Shipping
585,15 € Price plus shipping

Product group: WG02
Duct humidity and temperature sensors
with integrated pressure and differential pressure measuring transducer PREMASGARD® 814x - Modbus
Maintenance-free, microprocessor-controlled PREMASGARD® 814x - Modbus (series) pressure transmitters with Modbus connection, in an impact resistant plastic housing with quick-locking screws, optionally with/without display, with a plastic sinter filter (exchangeable), for accurate detection of relative humidity (0…100% r.H.) and temperature (–35...+80 °C) in ducts as well as for measuring differential pressure (max. –7000...7000 Pa) in air. Supplied including mounting flange and ASD-06 connection set (2m connecting hose, two pressure port nipples, screws).

The pressure measuring transducer serves to measure positive, negative or differential pressure in clean air and gaseous media. It is used in cleanroom, medical and filter engineering, ventilation and air conditioning ducts, spray booths and large-scale catering facilities, in filter monitoring and level measuring or frequency converter triggering.

A long-term stable digital humidity and temperature sensor and a pressure sensor with a piezoresistive measuring element guarantee precise measuring results. The measured values are used internally for calculating the following parametres, which can be retrieved via Modbus: temperature [°C], relative humidity [% r.H.], dew point [°C], absolute humidity [g/m³], mixture ratio [g/kg], enthalpy [kJ kg] (ignoring atmospheric air pressure), differential pressure [Pa], volume flow [m³/h], air density [kg/m³].
Innovative Modbus sensor device with galvanically separated RS485 interface, selectable bus termination resistance, DIP switches for setting the bus parametres and bus address in current-free state, LEDs for telegram status display, two separate push-in terminals and a large back-lit three-line display with customised programming in the 7-segment and dot-matrix ranges. The sensor is factory-calibrated and can be fine-tuned to ambient conditions by an expert.
Technical details
Voltage supply
24 V AC (± 20 %) and
15…36 V DC
Power consumption
< 4.8 W/ 24 V DC typical; < 6.8 VA/ 24 V AC typical; peak current 200 mA
Data points
Temperature, relative humidity,
differential pressure
Measuring range, humidity
0...100 % r. H.
Operating range, humidity
0...95 % r. H. (without dew formation)
Deviation of humidity
typical ± 2.0 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3.0 % r. H.
Measuring range, temperature
–35...+80 °C
Temperature deviation
typically ± 0.2 K at +25 °C
Sensor protection
plastic sinter filter, Ø 16 mm, L = 35 mm, exchangeable
(optional metal sinter filter, Ø 16 mm, L = 32 mm)
Media temperature
–20...+50 °C
Pressure connection
with metal connection nozzles for pressure hose Ø 6 mm
(optional on request with quick connect
for PVC fabric pressure hose Ø 6 mm)
Type of pressure
differential pressure
Zero point offset
< ± 0.7 % of final value
Above- below-pressure
máx. ± 50 kPa
Ambient temperature
–30...+70 °C
Medium
clean air and
non-aggressive, non-combustible gases
Bus protocol
Modbus (RTU mode),
address range 0...247 selectable
Signal filtering
4 s / 32 s
Process connection
by mounting flange, plastic
(included in the scope of delivery)
Protective tube
PLEUROFORM, material polyamide (PA6), with torsion protection, Ø 20 mm, vmax = 30 m/s (air)
without filter: NL = 202.5 mm / with plastic filter: NL = 235 mm (optional with metal filter: NL = 227 mm)
Electrical connection
0.2 - 1.5 mm², via push-in terminal
Cable connection
cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or
M12 connector according to DIN EN 61076-2-101 (optional on request)
Housing dimensions
126 x 90 x 50 mm (Tyr 2)
Cable gland
2x M 16 x 1.5; including strain relief, exchangeable
Long-term stability
± 1 %/ year
Sum of Linearity+hysteresis
< ± 1 % of final value
Media contacting parts
ms, Ni, Nylon, PU, Si, PVC with plasticisers
Temperature drift values
± 0.1 %/ °C
Temperature drift values
± 0.1 %/ °C
Protection class
III (according to EN 60 730)
Protection type
IP 65 (according to EN 60 529) housing only! (PLEUROFORM IP 30)
Standards
CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU