{"title":"CO2 sensors outside","description":"\u003cp\u003eOur maintenance-free surface-mounted CO2 sensors reliably measure the CO2 content of the air. Many devices also measure humidity, temperature and air quality (VOC). The sensors are used in offices, hotels, conference rooms, apartments, stores, etc.\u003c\/p\u003e","products":[{"product_id":"aufputzfuehler-aerasgard-aco2-modbus-modbus-rtu-1501-7110-6001-200","title":"AERASGARD® ACO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341416779,"sku":"1501-7110-6001-200","price":414.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus__tyr2-2xKV_maxi-mL_4c.png?v=1769649631"},{"product_id":"aufputzfuehler-aerasgard-aco2-modbus-lcd-modbus-rtu-display-1501-7110-6071-200","title":"AERASGARD® ACO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341482315,"sku":"1501-7110-6071-200","price":493.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus-Display__tyr2-2xKV_maxi-mL_4c.png?v=1769649616"},{"product_id":"aufputz-co2-sensor-co2-fuehler-aerasgard-aco2-sd-u-0-10v-1501-7110-1001-200","title":"AERASGARD® ACO2-SD-U","description":"Maintenance-free surface-mounted sensor AERASGARD® ACO2-SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-locking screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free surface-mounted sensor AERASGARD® ACO2-W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-locking screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341646155,"sku":"1501-7110-1001-200","price":270.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ACO2-SD-TYR2__tyr2_maxi-mL_4c.png?v=1769647846"},{"product_id":"aufputz-co2-sensor-co2-fuehler-aerasgard-aco2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-7110-7301-200","title":"AERASGARD® ACO2-W","description":"Maintenance-free surface-mounted sensor AERASGARD® ACO2-SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-locking screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free surface-mounted sensor AERASGARD® ACO2-W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-locking screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341744459,"sku":"1501-7110-7301-200","price":387.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ACO2-TYR2__tyr2_maxi-mL_4c.png?v=1769647879"},{"product_id":"aufputz-co2-sensor-co2-fuehler-aerasgard-aco2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-7110-7371-200","title":"AERASGARD® ACO2-W LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® ACO2-SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-locking screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free surface-mounted sensor AERASGARD® ACO2-W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-locking screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341809995,"sku":"1501-7110-7371-200","price":453.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ACO2-W-350ppm-OC__tyr2_maxi-mL_4c.png?v=1769647923"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-und-co2-gehalt-aerasgard-aftm-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-7116-7301-200","title":"AERASGARD® AFTM-CO2-W","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® AFTM - CO2 - W\/ ASGARD® AFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341842763,"sku":"1501-7116-7301-200","price":496.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2__tyr2-K_maxi-mL_4c.png?v=1769649830"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-und-co2-gehalt-aerasgard-aftm-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-7116-7371-200","title":"AERASGARD® AFTM-CO2-W LCD","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® AFTM - CO2 - W\/ ASGARD® AFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341941067,"sku":"1501-7116-7371-200","price":595.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-W-Display-350ppm-OC__tyr2-K_maxi-mL_4c.png?v=1769649904"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-und-co2-gehalt-aerasgard-aftm-lq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-7118-7301-500","title":"AERASGARD® AFTM-LQ-CO2-W","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® AFTM - CO2 - W\/ ASGARD® AFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341973835,"sku":"1501-7118-7301-500","price":650.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2__tyr2-K_maxi-mL_4c_e4620f9a-f728-4223-8b7d-34199d11cd5b.png?v=1769649932"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-und-co2-gehalt-aerasgard-aftm-lq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-7118-7371-500","title":"AERASGARD® AFTM-LQ-CO2-W LCD","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® AFTM - CO2 - W\/ ASGARD® AFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345217867,"sku":"1501-7118-7371-500","price":778.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-W-Display-350ppm-OC__tyr2-K_maxi-mL_4c_184cd81d-7a38-4c27-8a83-744379cb0578.png?v=1769650006"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-co2-modbus-modbus-rtu-1501-7116-6001-200","title":"AERASGARD® AFTM-CO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345283403,"sku":"1501-7116-6001-200","price":519.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus__tyr2-K-2xKV_maxi-mL_4c.png?v=1769649742"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-co2-modbus-lcd-modbus-rtu-display-1501-7116-6071-200","title":"AERASGARD® AFTM-CO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345348939,"sku":"1501-7116-6071-200","price":622.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus-Display__tyr2-K-2xKV_maxi-mL_4c.png?v=1769649721"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-lq-co2-modbus-modbus-rtu-1501-7118-6001-500","title":"AERASGARD® AFTM-LQ-CO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345414475,"sku":"1501-7118-6001-500","price":663.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus__tyr2-K-2xKV_maxi-mL_4c_e79938f9-82c6-4711-892b-6a274da0012e.png?v=1769649803"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-lq-co2-modbus-lcd-modbus-rtu-display-1501-7118-6071-500","title":"AERASGARD® AFTM-LQ-CO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345545547,"sku":"1501-7118-6071-500","price":785.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus-Display__tyr2-K-2xKV_maxi-mL_4c_22a66666-29e7-4d03-ac13-225791cdfa13.png?v=1769649782"},{"product_id":"aufputzfuehler-fuer-co2-gehalt-und-luftguete-aerasgard-alq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-7111-7301-500","title":"AERASGARD® ALQ-CO2-W","description":"Maintenance-free surface-mounted sensor AERASGARD® ALQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and day room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of buildings, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345905995,"sku":"1501-7111-7301-500","price":516.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-W__tyr2_maxi-mL_4c.png?v=1769649653"},{"product_id":"aufputzfuehler-fuer-co2-gehalt-und-luftguete-aerasgard-alq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-7111-7371-500","title":"AERASGARD® ALQ-CO2-W LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® ALQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and day room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of buildings, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255346200907,"sku":"1501-7111-7371-500","price":583.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-W-350ppm-OC__tyr2_maxi-mL_4c.png?v=1769649678"},{"product_id":"aufputz-luftqualitaets-voc-und-co2-fuehler-aerasgard-alq-co2-modbus-modbus-rtu-1501-7111-6001-500","title":"AERASGARD® ALQ-CO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255346594123,"sku":"1501-7111-6001-500","price":558.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus__tyr2-2xKV_maxi-mL_4c_4ff11e16-810c-403f-8e5d-bf7762eb3449.png?v=1769648677"},{"product_id":"aufputz-luftqualitaets-voc-und-co2-fuehler-aerasgard-alq-co2-modbus-lcd-modbus-rtu-display-1501-7111-6071-500","title":"AERASGARD® ALQ-CO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255346921803,"sku":"1501-7111-6071-500","price":653.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus-Display__tyr2-2xKV_maxi-mL_4c_68e2053a-7192-4613-a1ae-12d049ce41fa.png?v=1769648662"},{"product_id":"multifunktionaler-aufputzfuehler-fuer-temperatur-und-co2-gehalt-kalibrierfaehig-mit-aktivem-schaltendem-ausgang-aerasgard-atm-co2-sd-u-0-10v-1501-7112-1001-200","title":"AERASGARD® ATM-CO2-SD-U","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® ATM - CO2 - SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-locking screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The transmitter converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eThe transmitter is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255355146571,"sku":"1501-7112-1001-200","price":343.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-W__tyr2_maxi-mL_4c_edd936bd-891d-4a92-8431-bcf42fcb83c8.png?v=1769688405"},{"product_id":"aufputz-co2-sensor-co2-fuehler-aerasgard-aco2-sd-u-1501-7110-1001-600","title":"AERASGARD® ACO2-SD-U","description":"Maintenance-free surface-mounted sensor AERASGARD® ACO2-SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-locking screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free surface-mounted sensor AERASGARD® ACO2-W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-locking screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059369816395,"sku":"1501-7110-1001-600","price":270.11,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_9186e6d9-295f-4607-8177-2db10a654f88.jpg?v=1776486928"},{"product_id":"aufputz-co2-sensor-co2-fuehler-aerasgard-aco2-aw-1501-7110-e301-600","title":"AERASGARD® ACO2-AW","description":"Maintenance-free surface-mounted sensor AERASGARD® ACO2-SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-locking screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free surface-mounted sensor AERASGARD® ACO2-W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-locking screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059369881931,"sku":"1501-7110-E301-600","price":387.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_3a3d229e-3824-4361-85b6-b49b65039b27.jpg?v=1776486923"},{"product_id":"aufputz-co2-sensor-co2-fuehler-aerasgard-aco2-aw-lcd-1501-7110-e371-600","title":"AERASGARD® ACO2-AW LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® ACO2-SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-locking screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free surface-mounted sensor AERASGARD® ACO2-W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-locking screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059369914699,"sku":"1501-7110-E371-600","price":453.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_424ad8e0-c5d6-42fc-bd5d-39fa9659f6f2.jpg?v=1776486924"},{"product_id":"alq-co2-w","title":"ALQ-CO2-W","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57038730527051,"sku":"1501-7111-7301-600","price":516.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_2232133b-7004-465a-840a-23dd7d28bc2a.jpg?v=1776486807"},{"product_id":"aftm-lq-co2-modbus","title":"AFTM-LQ-CO2-Modbus","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57047463330123,"sku":"1501-7118-6001-600","price":663.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_933f83d8-c5cb-4277-9a1e-982d762a9d7f.jpg?v=1776486788"},{"product_id":"aftm-lq-co2-modbus-lcd","title":"AFTM-LQ-CO2-Modbus LCD","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57047463395659,"sku":"1501-7118-6071-600","price":785.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_d6fb8eba-dd4d-40ed-81c4-a19fb802f0e7.jpg?v=1776486795"},{"product_id":"alq-co2-modbus","title":"ALQ-CO2-Modbus","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57047463461195,"sku":"1501-7111-6001-600","price":558.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_d43051a6-91aa-452d-b6d9-08181642e4df.jpg?v=1776486799"},{"product_id":"aftm-lq-co2-w","title":"AFTM-LQ-CO2-W","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57236457488715,"sku":"1501-7118-7301-600","price":650.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2__tyr2-K_maxi-mL_4c_c2f54713-833c-4050-b56d-aa1a5501d43e.png?v=1778131582"},{"product_id":"alq-co2-w-lcd","title":"ALQ-CO2-W LCD","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57236457554251,"sku":"1501-7111-7371-600","price":583.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-W-350ppm-OC__tyr2_maxi-mL_4c_4e906a1a-51af-47b5-9538-9b00cdc88763.png?v=1778131587"}],"url":"https:\/\/www.spluss.de\/en\/collections\/outdoor-co2-sensors.oembed?page=2","provider":"S+S Regeltechnik","version":"1.0","type":"link"}