{"title":"Modbus air quality sensors","description":"","products":[{"product_id":"aufputzfuehler-aerasgard-aco2-modbus-modbus-rtu-1501-7110-6001-200","title":"AERASGARD® ACO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341416779,"sku":"1501-7110-6001-200","price":414.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus__tyr2-2xKV_maxi-mL_4c.png?v=1769649631"},{"product_id":"aufputzfuehler-aerasgard-aco2-modbus-lcd-modbus-rtu-display-1501-7110-6071-200","title":"AERASGARD® ACO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255341482315,"sku":"1501-7110-6071-200","price":493.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus-Display__tyr2-2xKV_maxi-mL_4c.png?v=1769649616"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-co2-modbus-modbus-rtu-1501-7116-6001-200","title":"AERASGARD® AFTM-CO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345283403,"sku":"1501-7116-6001-200","price":519.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus__tyr2-K-2xKV_maxi-mL_4c.png?v=1769649742"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-co2-modbus-lcd-modbus-rtu-display-1501-7116-6071-200","title":"AERASGARD® AFTM-CO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345348939,"sku":"1501-7116-6071-200","price":622.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus-Display__tyr2-K-2xKV_maxi-mL_4c.png?v=1769649721"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-lq-co2-modbus-modbus-rtu-1501-7118-6001-500","title":"AERASGARD® AFTM-LQ-CO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345414475,"sku":"1501-7118-6001-500","price":663.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus__tyr2-K-2xKV_maxi-mL_4c_e79938f9-82c6-4711-892b-6a274da0012e.png?v=1769649803"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-lq-co2-modbus-lcd-modbus-rtu-display-1501-7118-6071-500","title":"AERASGARD® AFTM-LQ-CO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255345545547,"sku":"1501-7118-6071-500","price":785.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus-Display__tyr2-K-2xKV_maxi-mL_4c_22a66666-29e7-4d03-ac13-225791cdfa13.png?v=1769649782"},{"product_id":"aufputz-luftqualitaets-voc-und-co2-fuehler-aerasgard-alq-co2-modbus-modbus-rtu-1501-7111-6001-500","title":"AERASGARD® ALQ-CO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255346594123,"sku":"1501-7111-6001-500","price":558.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus__tyr2-2xKV_maxi-mL_4c_4ff11e16-810c-403f-8e5d-bf7762eb3449.png?v=1769648677"},{"product_id":"aufputz-luftqualitaets-voc-und-co2-fuehler-aerasgard-alq-co2-modbus-lcd-modbus-rtu-display-1501-7111-6071-500","title":"AERASGARD® ALQ-CO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255346921803,"sku":"1501-7111-6071-500","price":653.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus-Display__tyr2-2xKV_maxi-mL_4c_68e2053a-7192-4613-a1ae-12d049ce41fa.png?v=1769648662"},{"product_id":"raum-feuchte-temperatur-und-co2-fuehler-bzw-messumformer-aerasgard-fsftm-co2-modbus-modbus-rtu-ohne-potentiometer-1501-9226-6001-162","title":"AERASGARD® FSFTM-CO2-Modbus","description":"The AERASGARD® FSFTM - CO2 - Modbus room climate sensor and measuring transducer in a flush-mounted housing, optionally with potentiometer, is used to measure the CO2 content, relative humidity and temperature of the air and to set setpoint values. The measured variables are queried via the Modbus interface. \u003cbr\u003e\u003cbr\u003e The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). A digital, long-term stable sensor is used for humidity and temperature measurement. The relative humidity [% r.H.] is the quotient of the water vapor partial pressure and the saturation vapor pressure at the respective gas temperature.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The flush-mounted sensor is installed in high-quality surface switch programs, preferably from Gira, Berker, Merten, Jung, Siemens or Busch-Jaeger (using a flush-mounted adapter, no setpoint possible), either individually or in combination with light switches, sockets, etc. It is used in non-aggressive applications. \u003cbr\u003e \u003cbr\u003e It is used in non-aggressive, dust-free environments, in refrigeration, air conditioning and clean room technology, in interiors such as living rooms, offices, hotels, etc.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255357768011,"sku":"1501-9226-6001-162","price":413.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/FSFTM-CO2-Modbus__maxi_4c.png?v=1769688938"},{"product_id":"raum-feuchte-temperatur-und-co2-fuehler-bzw-messumformer-aerasgard-fsftm-co2-modbus-p-modbus-rtu-potentiometer-1501-9226-6501-282","title":"AERASGARD® FSFTM-CO2-Modbus P","description":"The AERASGARD® FSFTM - CO2 - Modbus room climate sensor and measuring transducer in a flush-mounted housing, optionally with potentiometer, is used to measure the CO2 content, relative humidity and temperature of the air and to set setpoint values. The measured variables are queried via the Modbus interface. \u003cbr\u003e\u003cbr\u003e The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). A digital, long-term stable sensor is used for humidity and temperature measurement. The relative humidity [% r.H.] is the quotient of the water vapor partial pressure and the saturation vapor pressure at the respective gas temperature.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The flush-mounted sensor is installed in high-quality surface switch programs, preferably from Gira, Berker, Merten, Jung, Siemens or Busch-Jaeger (using a flush-mounted adapter, no setpoint possible), either individually or in combination with light switches, sockets, etc. It is used in non-aggressive applications. \u003cbr\u003e \u003cbr\u003e It is used in non-aggressive, dust-free environments, in refrigeration, air conditioning and clean room technology, in interiors such as living rooms, offices, hotels, etc.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255358685515,"sku":"1501-9226-6501-282","price":510.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/FSFTM-Modbus-P__maxi_4c_8d2b251b-1ae3-4f77-86b4-970cd2a1dcda.png?v=1769688952"},{"product_id":"kanalfuehler-aerasgard-kco2-modbus-modbus-rtu-1501-8110-6001-200","title":"AERASGARD® KCO2-Modbus","description":"Patented quality product (patent no. DE 10 2014 010 719.1) Maintenance-free duct sensor AERASGARD® KFTM - LQ- CO2 - Modbus (max. expansion stage) or KCO2\/ KLQ - CO2\/ KFTM - CO2 - Modbus with Modbus connection, automatic calibration, in impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), incl. mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC). Mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), the air quality or air quality (0...100 % VOC), the temperature (-35...+80 °C) and the relative humidity (0...100 % RH).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.Innovative Modbus sensor with galvanically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255363666251,"sku":"1501-8110-6001-200","price":414.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KCO2-KLQ-CO2-Modbus__tyr2-PA6-oF-2xKV_maxi-mL_4c.png?v=1769683542"},{"product_id":"kanalfuehler-aerasgard-kco2-modbus-lcd-modbus-rtu-display-1501-8110-6071-200","title":"AERASGARD® KCO2-Modbus LCD","description":"Patented quality product (patent no. DE 10 2014 010 719.1) Maintenance-free duct sensor AERASGARD® KFTM - LQ- CO2 - Modbus (max. expansion stage) or KCO2\/ KLQ - CO2\/ KFTM - CO2 - Modbus with Modbus connection, automatic calibration, in impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), incl. mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC). Mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), the air quality or air quality (0...100 % VOC), the temperature (-35...+80 °C) and the relative humidity (0...100 % RH).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.Innovative Modbus sensor with galvanically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255363830091,"sku":"1501-8110-6071-200","price":480.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KCO2-KLQ-CO2-Modbus-Display__tyr2-PA6-oF-2xKV_maxi-mL_4c.png?v=1769683522"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-kftm-co2-modbus-modbus-rtu-1501-8116-6001-200","title":"AERASGARD® KFTM-CO2-Modbus","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD\/ KFTM - CO2 - W\/ KFTM - CO2 - Wwith active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255366549835,"sku":"1501-8116-6001-200","price":424.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTM-LQ-CO2-Modbus__tyr2-PA-K-2xKV_maxi-mL_4c.png?v=1769683789"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-kftm-co2-modbus-lcd-modbus-rtu-display-1501-8116-6071-200","title":"AERASGARD® KFTM-CO2-Modbus LCD","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD\/ KFTM - CO2 - W\/ KFTM - CO2 - Wwith active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255366975819,"sku":"1501-8116-6071-200","price":518.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTM-LQ-CO2-Modbus-Display__tyr2-PA-K-2xKV_maxi-mL_4c.png?v=1769683762"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-kftm-lq-co2-modbus-modbus-rtu-1501-8118-6001-500","title":"AERASGARD® KFTM-LQ-CO2-Modbus","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD\/ KFTM - CO2 - W\/ KFTM - CO2 - Wwith active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-locking screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255367303499,"sku":"1501-8118-6001-500","price":555.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTM-LQ-CO2-Modbus__tyr2-PA-K-2xKV_maxi-mL_4c_efd61363-ccb6-4517-96d3-70f35eb051c6.png?v=1769683881"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-kftm-lq-co2-modbus-lcd-modbus-rtu-display-1501-8118-6071-500","title":"AERASGARD® KFTM-LQ-CO2-Modbus LCD","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD\/ KFTM - CO2 - W\/ KFTM - CO2 - Wwith active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255367598411,"sku":"1501-8118-6071-500","price":653.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTM-LQ-CO2-Modbus-Display__tyr2-PA-K-2xKV_maxi-mL_4c_2894ca70-c942-4d22-9712-41f9a5fb793f.png?v=1769683842"},{"product_id":"kanal-luftqualitaets-voc-und-co2-fuehler-aerasgard-klq-co2-modbus-modbus-rtu-1501-8111-6001-500","title":"AERASGARD® KLQ-CO2-Modbus","description":"\u003cp\u003ePatented quality product (patent no. DE 10 2014 010 719.1)Maintenance-free duct sensor AERASGARD® KFTM - LQ- CO2 - Modbus (max. expansion stage) or KCO2\/ KLQ - CO2\/ KFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), incl. mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), air quality (0...100 % VOC), incl. display. Mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), the air quality or air quality (0...100 % VOC), the temperature (-35...+80 °C) and the relative humidity (0...100 % RH). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus:  Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.Innovative Modbus sensor with galvanically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003c\/p\u003e","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255371792715,"sku":"1501-8111-6001-500","price":467.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KCO2-KLQ-CO2-Modbus__tyr2-PA6-oF-2xKV_maxi-mL_4c_4e2f873b-a40e-426a-82d4-da36af00210b.png?v=1769680545"},{"product_id":"kanal-luftqualitaets-voc-und-co2-fuehler-aerasgard-klq-co2-modbus-lcd-modbus-rtu-display-1501-8111-6071-500","title":"AERASGARD® KLQ-CO2-Modbus LCD","description":"\u003cp\u003ePatented quality product (patent no. DE 10 2014 010 719.1)Maintenance-free duct sensor AERASGARD® KFTM - LQ- CO2 - Modbus (max. expansion stage) or KCO2\/ KLQ - CO2\/ KFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), incl. mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), air quality (0...100 % VOC), incl. display. Mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), the air quality or air quality (0...100 % VOC), the temperature (-35...+80 °C) and the relative humidity (0...100 % RH). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus:  Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.Innovative Modbus sensor with galvanically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003c\/p\u003e","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255372480843,"sku":"1501-8111-6071-500","price":546.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KCO2-KLQ-CO2-Modbus-Display__tyr2-PA6-oF-2xKV_maxi-mL_4c_a66eb0de-d632-476c-a6b1-1992f982137c.png?v=1769680525"},{"product_id":"raum-luftguetefuehler-aerasgard-rco2-modbus-modbus-rtu-1501-61b0-6001-200","title":"AERASGARD® RCO2-Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255374315851,"sku":"1501-61B0-6001-200","price":300.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Baldur2_maxi-mL_4c.png?v=1769689404"},{"product_id":"raum-luftguetefuehler-aerasgard-rco2-modbus-lcd-modbus-rtu-display-1501-61b0-6021-200","title":"AERASGARD® RCO2-Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255375003979,"sku":"1501-61B0-6021-200","price":355.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-Display__baldur2_maxi-mL_4c.png?v=1769689191"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-co2-modbus-modbus-rtu-ohne-potentiometer-1501-61b6-6001-200","title":"AERASGARD® RFTM-CO2-Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255377658187,"sku":"1501-61B6-6001-200","price":354.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_700a16ec-c0a5-4a9f-ba19-e79b0da8b8dc.png?v=1762857375"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-co2-modbus-lcd-modbus-rtu-display-ohne-potentiometer-1501-61b6-6021-200","title":"AERASGARD® RFTM-CO2-Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255377789259,"sku":"1501-61B6-6021-200","price":409.63,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-Display__baldur2_maxi-mL_4c_8f38cd2b-57ac-4660-9e89-be1dd6015067.png?v=1762857402"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-co2-modbus-p-modbus-rtu-potentiometer-1501-61b6-6501-271","title":"AERASGARD® RFTM-CO2-Modbus P","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255378084171,"sku":"1501-61B6-6501-271","price":392.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RTR-S-011__baldur2_maxi-mL_4c_ae6acdf7-094b-4a9b-a683-d11aea1bf433.png?v=1762857420"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-rftm-co2-modbus-p-lcd-modbus-rtu-display-potentiometer-1501-61b6-6521-271","title":"AERASGARD® RFTM-CO2-Modbus P LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255378379083,"sku":"1501-61B6-6521-271","price":447.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-P-Display__baldur2_maxi-mL_4c.png?v=1762857439"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftqualitaet-voc-feinstaub-pm-und-co2-aerasgard-rftm-ps-lq-co2-modbus-modbus-rtu-1501-2119-6001-500","title":"AERASGARD® RFTM-PS-LQ-CO2 Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255381524811,"sku":"1501-2119-6001-500","price":621.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_6e300a67-1003-4ba9-93b1-50a9f588c950.png?v=1762857894"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftqualitaet-voc-feinstaub-pm-und-co2-aerasgard-rftm-ps-lq-co2-modbus-lcd-modbus-rtu-display-display-1501-2119-6021-500","title":"AERASGARD® RFTM-PS-LQ-CO2 Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255381983563,"sku":"1501-2119-6021-500","price":676.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-PS-CO2-Modbus-Display-index6__baldur2_maxi-mL_4c.png?v=1762857930"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-pm-aerasgard-rftm-ps-modbus-modbus-rtu-1501-2116-6001-200","title":"AERASGARD® RFTM-PS-Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255387980107,"sku":"1501-2116-6001-200","price":409.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_25f5777b-450e-409b-8c98-f9ea5fd82cd4.png?v=1762857968"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-und-pm-aerasgard-rftm-ps-modbus-lcd-modbus-rtu-display-1501-2116-6021-200","title":"AERASGARD® RFTM-PS-Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255389126987,"sku":"1501-2116-6021-200","price":471.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-PS-CO2-Modbus-Display-68myg__baldur2_maxi-mL_4c.png?v=1762858005"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-modbus-modbus-rtu-1501-61b1-6001-500","title":"AERASGARD® RLQ-CO2-Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003cp\u003e\u003c\/p\u003e","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255398695243,"sku":"1501-61B1-6001-500","price":440.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_a51309d4-5c5e-46fd-a646-c9a6178874dd.png?v=1769689446"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-modbus-lcd-modbus-rtu-display-1501-61b1-6021-500","title":"AERASGARD® RLQ-CO2-Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003cp\u003e\u003c\/p\u003e","brand":"AERASGARD","offers":[{"title":"Default Title","offer_id":51255399088459,"sku":"1501-61B1-6021-500","price":495.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-Display__baldur2_maxi-mL_4c_76dcc3b8-931a-4436-9eb0-b5be4cad4a41.png?v=1769689426"},{"product_id":"multi-sensor-modbus-ams01-modbus-lcd-3con-0107-1005-000","title":"Multi-Sensor Modbus AMS01-MODBUS LCD","description":"The maintenance-free microprocessor-controlled AMSxx-MODBUS measuring device combines a large number of measured variables in various possible combinations. It is the perfect device for implementing needs-based air conditioning while taking the relevant measured variables into account. Combinations are possible for measuring humidity \u0026 temperature, carbon dioxide, carbon monoxide, air quality (VOC), particulate matter, atmospheric \/ barometric air pressure and differential pressure. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The detection range of the sensors is designed for standard HVAC applications for monitoring living and conference room, workplace and production facilities. However, special designs, other measuring ranges and measured variables can also be implemented on request. Demand-based ventilation, increased well-being and customer benefit, increased comfort and a reduction in operating costs through energy savings are just some of the results of using this compact device. The high-quality BoCube® housing series with hinge lock technology and the approx. 4-inch graphic LCD display perfectly match the design and quality standards of this device. Configuration (bus address, transmission mode, baud rate, etc.) is quick and easy using the self-explanatory menu. Among other things, fine adjustments to individual measured variables, the initiation of VOC and\/or CO2 calibrations and changes to the display can be made via corresponding registers.","brand":"spluss-regeltechnik","offers":[{"title":"Default Title","offer_id":51255434477899,"sku":"3CON-0107-1005-000","price":924.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Consens_Multimodbus_standard_maxi_4c.png?v=1770213204"},{"product_id":"multi-sensor-modbus-ams02-modbus-lcd-3con-0107-1006-000","title":"Multi-Sensor Modbus AMS02-MODBUS LCD","description":"The maintenance-free microprocessor-controlled AMSxx-MODBUS measuring device combines a large number of measured variables in various possible combinations. It is the perfect device for implementing needs-based air conditioning while taking the relevant measured variables into account. Combinations are possible for measuring humidity \u0026 temperature, carbon dioxide, carbon monoxide, air quality (VOC), particulate matter, atmospheric \/ barometric air pressure and differential pressure. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The detection range of the sensors is designed for standard HVAC applications for monitoring living and conference room, workplace and production facilities. However, special designs, other measuring ranges and measured variables can also be implemented on request. Demand-based ventilation, increased well-being and customer benefit, increased comfort and a reduction in operating costs through energy savings are just some of the results of using this compact device. The high-quality BoCube® housing series with hinge lock technology and the approx. 4-inch graphic LCD display perfectly match the design and quality standards of this device. Configuration (bus address, transmission mode, baud rate, etc.) is quick and easy using the self-explanatory menu. Among other things, fine adjustments to individual measured variables, the initiation of VOC and\/or CO2 calibrations and changes to the display can be made via corresponding registers.","brand":"spluss-regeltechnik","offers":[{"title":"Default Title","offer_id":51255435264331,"sku":"3CON-0107-1006-000","price":947.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Consens_Multimodbus_standard_maxi_4c.png?v=1770213204"},{"product_id":"multi-sensor-modbus-ams03-modbus-lcd-3con-0107-1007-000","title":"Multi-Sensor Modbus AMS03-MODBUS LCD","description":"The maintenance-free microprocessor-controlled AMSxx-MODBUS measuring device combines a large number of measured variables in various possible combinations. It is the perfect device for implementing needs-based air conditioning while taking the relevant measured variables into account. Combinations are possible for measuring humidity \u0026 temperature, carbon dioxide, carbon monoxide, air quality (VOC), particulate matter, atmospheric \/ barometric air pressure and differential pressure. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The detection range of the sensors is designed for standard HVAC technology applications for monitoring living and conference room, workplace and production facilities. However, special designs, other measuring ranges and measured variables can also be implemented on request. Demand-based ventilation, increased well-being and customer benefit, increased comfort and a reduction in operating costs through energy savings are just some of the results of using this compact device. The high-quality BoCube® housing series with hinge lock technology and the approx. 4-inch graphic LCD display perfectly match the design and quality standards of this device. Configuration (bus address, transmission mode, baud rate, etc.) is quick and easy using the self-explanatory menu. Among other things, fine adjustments to individual measured variables, the initiation of VOC and\/or CO2 calibrations and changes to the display can be made via corresponding registers.","brand":"spluss-regeltechnik","offers":[{"title":"Default Title","offer_id":51255435657547,"sku":"3CON-0107-1007-000","price":1024.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Consens_Multimodbus_standard_maxi_4c.png?v=1770213204"},{"product_id":"multi-sensor-modbus-ams04-modbus-lcd-3con-0107-1008-000","title":"Multi-Sensor Modbus AMS04-MODBUS LCD","description":"The maintenance-free microprocessor-controlled AMSxx-MODBUS measuring device combines a large number of measured variables in various possible combinations. It is the perfect device for implementing needs-based air conditioning while taking the relevant measured variables into account. Combinations are possible for measuring humidity \u0026 temperature, carbon dioxide, carbon monoxide, air quality (VOC), particulate matter, atmospheric \/ barometric air pressure and differential pressure. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The detection range of the sensors is designed for standard HVAC technology applications for monitoring living and conference room, workplace and production facilities. However, special designs, other measuring ranges and measured variables can also be implemented on request. Demand-based ventilation, increased well-being and customer benefit, increased comfort and a reduction in operating costs through energy savings are just some of the results of using this compact device. The high-quality BoCube® housing series with hinge lock technology and the approx. 4-inch graphic LCD display perfectly match the design and quality standards of this device. Configuration (bus address, transmission mode, baud rate, etc.) is quick and easy using the self-explanatory menu. Among other things, fine adjustments to individual measured variables, the initiation of VOC and\/or CO2 calibrations and changes to the display can be made via corresponding registers.","brand":"spluss-regeltechnik","offers":[{"title":"Default Title","offer_id":51255435919691,"sku":"3CON-0107-1008-000","price":850.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Consens_Multimodbus_standard_maxi_4c.png?v=1770213204"},{"product_id":"multi-sensor-modbus-ams05-modbus-lcd-3con-0107-1009-000","title":"Multi-Sensor Modbus AMS05-MODBUS LCD","description":"The maintenance-free microprocessor-controlled AMSxx-MODBUS measuring device combines a large number of measured variables in various possible combinations. It is the perfect device for implementing needs-based air conditioning while taking the relevant measured variables into account. Combinations are possible for measuring humidity \u0026 temperature, carbon dioxide, carbon monoxide, air quality (VOC), particulate matter, atmospheric \/ barometric air pressure and differential pressure. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The detection range of the sensors is designed for standard HVAC technology applications for monitoring living and conference room, workplace and production facilities. However, special designs, other measuring ranges and measured variables can also be implemented on request. Demand-based ventilation, increased well-being and customer benefit, increased comfort and a reduction in operating costs through energy savings are just some of the results of using this compact device. The high-quality BoCube® housing series with hinge lock technology and the approx. 4-inch graphic LCD display perfectly match the design and quality standards of this device. Configuration (bus address, transmission mode, baud rate, etc.) is quick and easy using the self-explanatory menu. Among other things, fine adjustments to individual measured variables, the initiation of VOC and\/or CO2 calibrations and changes to the display can be made via corresponding registers.","brand":"spluss-regeltechnik","offers":[{"title":"Default Title","offer_id":51255436083531,"sku":"3CON-0107-1009-000","price":831.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Consens_Multimodbus_standard_maxi_4c.png?v=1770213204"},{"product_id":"multi-sensor-modbus-ams06-modbus-lcd-3con-0107-1010-000","title":"Multi-Sensor Modbus AMS06-MODBUS LCD","description":"The maintenance-free microprocessor-controlled AMSxx-MODBUS measuring device combines a large number of measured variables in various possible combinations. It is the perfect device for implementing needs-based air conditioning while taking the relevant measured variables into account. Combinations are possible for measuring humidity \u0026 temperature, carbon dioxide, carbon monoxide, air quality (VOC), particulate matter, atmospheric \/ barometric air pressure and differential pressure. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The detection range of the sensors is designed for standard HVAC applications for monitoring living and conference room, workplace and production facilities. However, special designs, other measuring ranges and measured variables can also be implemented on request. Demand-based ventilation, increased well-being and customer benefit, increased comfort and a reduction in operating costs through energy savings are just some of the results of using this compact device. The high-quality BoCube® housing series with hinge lock technology and the approx. 4-inch graphic LCD display perfectly match the design and quality standards of this device. Configuration (bus address, transmission mode, baud rate, etc.) is quick and easy using the self-explanatory menu. Among other things, fine adjustments to individual measured variables, the initiation of VOC and\/or CO2 calibrations and changes to the display can be made via corresponding registers.","brand":"spluss-regeltechnik","offers":[{"title":"Default Title","offer_id":51255436116299,"sku":"3CON-0107-1010-000","price":908.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Consens_Multimodbus_standard_maxi_4c.png?v=1770213204"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1321c-rh-co2-mod-modbus-rtu-0-10v-weiss-24-v-ac-dc-rym1-3211-m610-000","title":"RYMASKON® RYM 1321C-RH-CO2-MOD","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255623385419,"sku":"RYM1-3211-M610-000","price":375.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1301__persp_maxi-mL_4c_1750c2c2-93e7-4995-803f-5a7d3ddf4946.png?v=1762901294"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1321c-rh-co2-mod-b-modbus-rtu-0-10v-weiss-24-v-ac-dc-rym1-3211-m610-001","title":"RYMASKON® RYM 1321C-RH-CO2-MOD-B","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255623418187,"sku":"RYM1-3211-M610-001","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1301-B___persp_maxi-mL_4c_479affc3-1a2e-4139-97cf-4a75b58d02a5.png?v=1762901111"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1321c-rh-co2-mod-bb-modbus-rtu-0-10v-weiss-24-v-ac-dc-rym1-3211-m610-002","title":"RYMASKON® RYM 1321C-RH-CO2-MOD-BB","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255624663371,"sku":"RYM1-3211-M610-002","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1301-BB__persp_maxi-mL_4c_126f4522-e37d-4b78-a2af-16b8ba1f9910.png?v=1762901154"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1321c-rh-co2-mod-l-modbus-rtu-0-10v-weiss-24-v-ac-dc-rym1-3211-m610-003","title":"RYMASKON® RYM 1321C-RH-CO2-MOD-L","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255624696139,"sku":"RYM1-3211-M610-003","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1301-L___persp_maxi-mL_4c_021b4bb6-7d51-4897-ba80-6f3609c8c5c0.png?v=1762901241"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1321c-rh-co2-mod-bl-modbus-rtu-0-10v-weiss-24-v-ac-dc-rym1-3211-m610-005","title":"RYMASKON® RYM 1321C-RH-CO2-MOD-BL","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255624728907,"sku":"RYM1-3211-M610-005","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1301-LB__persp_maxi-mL_4c_cc0f55c7-b007-4416-a51b-8b22a1fe0d15.png?v=1762901198"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1322c-rh-co2-mod-modbus-rtu-0-10v-schwarz-24-v-ac-dc-rym1-3221-m610-000","title":"RYMASKON® RYM 1322C-RH-CO2-MOD","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255629054283,"sku":"RYM1-3221-M610-000","price":375.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1302__persp_maxi-mL_4c_cff1bf21-076a-47b8-9ccd-95e61300c27f.png?v=1762901731"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1322c-rh-co2-mod-b-modbus-rtu-0-10v-schwarz-24-v-ac-dc-rym1-3221-m610-001","title":"RYMASKON® RYM 1322C-RH-CO2-MOD-B","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255629185355,"sku":"RYM1-3221-M610-001","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1302-B___persp_maxi-mL_4c_ed044384-65be-4b95-9c8d-cb4f5fc808f8.png?v=1762901556"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1322c-rh-co2-mod-bb-modbus-rtu-0-10v-schwarz-24-v-ac-dc-rym1-3221-m610-002","title":"RYMASKON® RYM 1322C-RH-CO2-MOD-BB","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255629480267,"sku":"RYM1-3221-M610-002","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1302-BB__persp_maxi-mL_4c_04e65d2c-3475-4f7c-b270-19d913fd7f66.png?v=1762901600"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1322c-rh-co2-mod-l-modbus-rtu-0-10v-schwarz-24-v-ac-dc-rym1-3221-m610-003","title":"RYMASKON® RYM 1322C-RH-CO2-MOD-L","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255629971787,"sku":"RYM1-3221-M610-003","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1302-L___persp_maxi-mL_4c_fcfdfc78-4cac-49d4-ba63-9b75d6736087.png?v=1762901687"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1322c-rh-co2-mod-bl-modbus-rtu-0-10v-schwarz-24-v-ac-dc-rym1-3221-m610-005","title":"RYMASKON® RYM 1322C-RH-CO2-MOD-BL","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255630889291,"sku":"RYM1-3221-M610-005","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1302-LB__persp_maxi-mL_4c_2ed36753-3bb6-4ae0-8f4d-2682b4c493d0.png?v=1762901643"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1361c-rh-co2-mod-modbus-rtu-0-10v-schaltend-weiss-24-v-ac-dc-rym1-3611-m610-000","title":"RYMASKON® RYM 1361C-RH-CO2-MOD","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or {{c603aa0a684cda468691en147fc89e9f}} communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255632757067,"sku":"RYM1-3611-M610-000","price":375.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1301__persp_maxi-mL_4c_81aabe1b-0030-4bd5-bd7e-2ab99eefb94a.png?v=1762902130"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1361c-rh-co2-mod-b-modbus-rtu-0-10v-schaltend-weiss-24-v-ac-dc-rym1-3611-m610-001","title":"RYMASKON® RYM 1361C-RH-CO2-MOD-B","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255632888139,"sku":"RYM1-3611-M610-001","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1301-B___persp_maxi-mL_4c_7ba6c792-1dbd-472f-add2-32d1d346d091.png?v=1762901986"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1361c-rh-co2-mod-bb-modbus-rtu-0-10v-schaltend-weiss-24-v-ac-dc-rym1-3611-m610-002","title":"RYMASKON® RYM 1361C-RH-CO2-MOD-BB","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255632986443,"sku":"RYM1-3611-M610-002","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1301-BB__persp_maxi-mL_4c_dea471d8-fb32-4c64-bd21-f51fdbd4209e.png?v=1762902022"},{"product_id":"raumbediengeraet-controller-24-v-rymaskon-rym-1361c-rh-co2-mod-l-modbus-rtu-0-10v-schaltend-weiss-24-v-ac-dc-rym1-3611-m610-003","title":"RYMASKON® RYM 1361C-RH-CO2-MOD-L","description":"The Rymaskon® 1000 series room operating units are designed for controlling (up to 5 climate zones) in residential, hotel and office rooms and individually regulate the heating, cooling and fan levels of the interior. The controller variants can be operated as stand-alone devices thanks to the integrated PI, PWM or 2-\/3-point control functions. The product family is characterized by its elegant design, intuitive operation and the many possible combinations of the individual components. \u003cbr\u003e The Rymaskon® 1000 C room operating units (controllers) are used to control and regulate heating convectors and fan coil units. Depending on the type variant, the devices are available with analog outputs (0 -10 V) and with digital \/ relay outputs for controlling heating valves, cooling valves, 6-way valves, staged fans or EC fans. Control is via PI, PWM or 2-\/3-point control. The changeover function can be used to operate 2- and 4-pipe systems.\u003cbr\u003eThe Modbus or W-Modbus communication interface enables the climate parameters on the controller to be changed and monitored at any time via the BMS. In addition, the sun protection functions (external blinds, venetian blinds) or light (with dimming function) can be controlled via the bus. The visual display is shown on a 2\" TFT display and operation is via capacitive buttons (touch keys). \u003cbr\u003e \u003cbr\u003eIn addition to the integrated temperature and humidity sensor, optional sensors for CO2 and VOC are available. There is also an input for a passive temperature sensor (NTC10K) and an input for a potential-free contact. For example, a window contact or a condensation monitor can be connected. This gives you all the options you need to air-condition rooms flexibly and individually. \u003cbr\u003eAll device types are available in the timeless Iduna 3 housing (112 x 89.5 x 24 mm) in white or black. Wall mounting is on standard flush-mounted boxes.","brand":"RYMASKON","offers":[{"title":"Default Title","offer_id":51255633084747,"sku":"RYM1-3611-M610-003","price":439.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RYM-1301-L___persp_maxi-mL_4c_82b589fe-2039-4532-b3ac-a602d164d092.png?v=1762902094"}],"url":"https:\/\/www.spluss.de\/en\/collections\/modbus-air-quality-sensors.oembed?page=12","provider":"S+S Regeltechnik","version":"1.0","type":"link"}