Outside temperature/ wet room temperature measuring transducers ATM 2 - VA
temperature Temperature

Outside temperature/ wet room temperature measuring transducers THERMASGARD® ATM 2 - VA

Product group: WG02I

In Stock

Usually ships in 1 to 3 days
388,67 €
462,52 € incl. VAT + shipping
+

Description

Outside temperature/ wet room temperature measuring transducers THERMASGARD® ATM 2 - VA
Calibratable THERMASGARD® ATM 2 - VA outside temperature measuring transducer with eight switchable measuring ranges, external sensor, continuous output, rugged housing in V4A stainless steel, with cable gland or M12 connector according to DIN EN 61076-2-101.

The transmitter serves to detect outside temperatures and temperatures in wet rooms. It is used e.g. on outside walls, in cold storage buildings and greenhouses, in the industrial sector and in agriculture. Installation in outdoor areas is preferably performed at the north side of a building or in a protected place. In cases of direct solar irradiation, we recommend using our WS 01 or WS 03 sun and ball-impact protection hood (accessory).
The sensor is factory-calibrated and can be fine-tuned to ambient conditions by an expert.

Technical details

Power consumption
< 1,0 W/ 24 V DC
< 2,2 VA/ 24 V AC
Temperature deviation
typically ± 0.2 K at +25 °C
Sensor
Pt1000, DIN EN 60751, class B
(Perfect Sensor Protection)
Connection type
2-wire connection
Measuring ranges
multi-range switching with 8 switchable measuring ranges,
see table (other ranges optional)
operating range –30...+70 °C
with manual zero point correction (± 10 K)
Ambient temperature
Measuring transducer –30...+70 °C
Process connection
by screws
Protective tube
stainless steel V4A (1.4571), Ø 6 mm, NL = 65 mm
Electrical connection
0.14 - 1.5 mm² via terminal screws
Housing
stainless steel V4A (1.4571),
with non-distortion cover bolting,
impact-resistant, high EMI shielding,
corrosion, temperature, UV and weathering resistant
Housing dimensions
143 x 97 x 61 mm (Tyr 2E)
Permissible air humidity
< 95 % RH, non-precipitating air
Protection class
III (according to EN 60 730)
Protection type
IP 65 (according to EN 60 529) Housing tested,
TÜV SÜD, Report No.713139052 (Tyr 1)
Standards
CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU